Complying With ERS (European Respiratory Society )Standard.
The Production Processes And Equipment Standard have passed ISO13485 And The EU CE Certifications.
Accurately, Automatic And Real-time For Controlling The Pressure.
Stabilized Pressure Within The Set Range.
Real-time Data Storage For Easy Traceability.
Automatic Fault Diagnosis, Warning In Advance By Alarm And Light Function.
Equipped With AC & Polymer Lithium Battery To Keep Excellent Stability For The Pressure.
Equipped With Professional High-precision Pressure Sensor.
Digital LCD Display Screen.
According To The EU Medical Device MDR, Classified As Ⅱ a.
1. The Necessity:
1.1 Usually, The Aerocyst Pressure Needs To Be Measured By Medical Staffs At Intervals, To Confirm Whether The Pressure Is Within The Set Range. Greatly It Increases The Workload of Nurses.
If The Pressure Is Less Than The Minimum Sealing Pressure, The Liquids Such As Mucus In The Mouth, It Will Flow Into The lungs, Causing The Pulmonary Infection, And Increasing The Incidence of Ventilator-related Pneumonia To The Patients.
If The Pressure Inside The Aerocyst Is Excessive, It Will Cause The Patient’s Airway Wall To Be Squeezed And Compressed, And The Prolonged Compression Will Damage The Patient’s Trachea.
1.2 CONGLAY Brand Cuff Pressure Monitor Products Solved All Above Problems, In Real Time Automatically Supervise And Control The Pressure In The Aerocyst So As To Keep The Pressure In Preset Range, To Store And Lead Out The Data In Real Time, Automatic Fault Diagnosis By Operating The Audio & Optical Control of Supervision System, Effectively To Reduce The Risks of VAP, In Order To Achieve For Reducing The Work Intensities To The Medical Staffs.
1. The Main Technical Parameters For Cuff Pressure Controller Device.
1.1 Dimension (L*W*H mm): 180×140×55;
1.2 Display Screen:100×77mm, Display Screen With LCD
1.3 Power Supply Voltage: AC100-240V 50/60Hz,DC3.7V
1.4 Pressure Controlling Range: 0-95 cmH2O
1.5 Pressure Setting Range: 0-70 cmH2O,Minimum Adjustment Capacity: 1 cmH2O
1.6 Deflating Time Setting: 0~60s,Adjustable,The Minimum Adjuctment: 1s
1.7 Leak-proofness : < 2 cmH2O/min
1.8 The Noise During Operation:< 55dB(A)
1.9 Power Supplying Time For Built-in Polymer Lithium Battery(H): > 8
1.10 Size of Connecting Tube(m):1.8
1.11 Size of Power Adapter Cable(m):1.8(±0.05m)
1.12 Operation Model : Continuous Operation
1.13 Services Life:5 Years
1.14 Operating Conditions:
① The Ambient Temperature Range:5℃~40℃
② The Relative Humidity Range:<85%
③ The Atmospheric Pressure Range:70~106KPa
Wuxi Conglay Medical Technology Co., Ltd.
Add:: 4th Floor, 1719-12 Huishan Main Road, Huishan Economic Development Zone, Wuxi City, Jiagsu Province, China
Tel:+86 510 83593979
E-mail:overseas@conglay.com